Filter Results By:

Products

Applications

Manufacturers

Showing results: 136 - 147 of 147 items found.

  • Circuit Breaker Analyzers & Timers

    IBEKO Power AB

    CAT circuit breaker analyzers and timers are advanced standalone or a PC controlled instruments for circuit breaker maintenance. Typical application areas of CAT instruments are medium and high voltage substations at electric power generation, transmission, and factories of switchgear. Also, industrial environments and electric power distribution are suitable application areas for these circuit breaker testing instruments.DV Power CAT circuit breaker testing instruments are portable and lightweight. They are designed for performing mechanical operations intended for circuit breakers testing according to standards IEC 62271-100 and IEEE C37.09.These instruments measure:the timing of main contacts, pre-insertion resistor contacts, auxiliary contacts operations,coil currents,motion parameters,voltage recording,main circuit resistance,arcing contacts wipe,and any relevant analog signal.Motion transducer channels provide measuring a displacement of the circuit breaker moving parts, contact wipe, over-travel, rebound, damping time, and average velocity. Even more, CAT circuit breaker analyzer optionally has a built-in micro-ohmmeter. Hence, it provides the main circuit resistance measurement and dynamic resistance measurement. Dynamic resistance measurement is an effective method for arcing contacts condition assessment.

  • Load Cell Power Supply

    MODEL PSMR - Transducer Techniques, Inc

    The PSM-R is a self contained AC power bridge excitation supply. This device consists of a low interwinding capacitance AC transformer and a high stability adjustable linear regulator designed specifically for driving transducer bridges. DC excitation is adjustable from 4 to 15 volts output and is capable of supplying 0 to 150 mA in output current. It features remote sensing to eliminate line drop errors and very low noise. It can also be used as a high quality voltage source or reference in many applications. AC input requirements are 105 to 125 VAC at 60 Hz.

  • High Speed Data Logger

    9330 - Interface Inc.

    The Model 9330 displays 24-bit resolution and has an impressive 3750Hz update rate. Incorporating peak and valley capture, it can store up to 6 sensor calibrations and measurements from load cells or torque transducers can be logged at 1000Hz to a standard SD card. This data can then be downloaded to a PC via the built-in USB port and Windows compatible software for off-site analysis. Adding further versatility, the rechargeable battery can power up to 4 x 350 ohm sensors, but also offers up to 300 hours stand by time and up to 20 hours continue use.

  • TE-Metrology

    HIGHVOLT Prüftechnik Dresden GmbH

    The TE measurement complements the high voltage test and is part of the routine and type testing of numerous electrical devices. It is one of the most important non-destructive methods for detecting faults in electrical installations. The breakdown of an insulating material usually occurs at an internal weak point, which usually already shows a partial discharge activity in advance. For this reason, measuring partial discharges can help prevent costly damage. The TE measurement is thus used for quality testing and diagnosis in the factory as well as during on-site testing of cables, GIS, power transformers and transducers or rotating machinery and their components

  • 6000 Series Analog I/O Modules

    Pacific Instruments, Inc.

    Series 6000 analog I/O modules condition, amplify, filter and digitize signals from virtually any transducer. All modules have conditioning & amplifier per channel and nearly all modules allow for setting bridge completion, shunt calibration, transducer power, gain, etc. individually per channel. Following the conditioning/amplifier stage, multi-pole Bessel or Butterworth analog filters are provided on each channel and can be set or bypassed individually by program control. A number of the modules include a high level analog output providing a conditioned/filtered output to a redundant, external A/D system. A 16-Bit Successive Approximation A/D follows the analog filter stage. Some modules use a single A/D with sample and hold while others have an A/D per channel. Sample rates are programmable per channel to easily accommodate mixing high and low speed measurements into a single data stream. Programmable hardware based warnings and alarms are included in the channel-by-channel architecture and are detected by digital output modules in the system, providing an ultra-low latency control capability directly from the data acquisition system.

  • Flexible Current Sensor Probe

    CTA - Powertek LLC

    The CTA current sensors convert ac current to an isolated 0-5A current with available ranges from 100A to 10,000A. Because the current sensors are flexible split core, installation is possible without shutting down the LV electrical supply, avoiding expensive down-time costs. Typical applications are retrospective energy monitoring in factories, offices buildings, process control data logging systems, where power, energy and current monitoring is important. Typical applications are factories, offices buildings, ac/dc VFD drives, welding, power conversion and power distribution. For all CTA current sensor models, a NIST/NPL (UKAS) traceable calibration certificate and certificate of conformance is supplied. All CTA sensors use UL94V0 or CSA approved materials. The CTA flexible current sensors are suited to permanent or semi permanent installation. The coil sensor is durable, lightweight, flexible and will easily clip-around a power cable. The 5A output from the CTA current sensor connects direct to installed metering, rotary metering or current transducers.

  • LED Power Driver ATS

    8491 - Chroma ATE Inc.

    1. DC Electronic Load : Chroma 6310A/6330A Series2. Transducer Unit/Module*1 : Chroma A849101/A849102, A849103, A8491043. Time/Noise Analyzer : Chroma 80611 & 80611N card4. Sytem Controller*2 : Industrial PC5. DC Source: Chroma 62000P Series6. Digital Power Meter : Chroma 66200 Series7. OVP/Short Circuit Tester : Chroma 806128. ON/OFF Controller : Chroma 80613*1 : A849101 transfers UUT output signal to voltage signal, and measure by 84911 LED power driver measurement card (200kHz). The optional 80611N Noise card is required for 20MHz ripplecurrent measurement.*2 : The controller includes both 84911 LED Power Driver measurement card and 84903 control card.- 84911: Measure rms current, dimming current/frequency/duty, timing, power & ripple current (200kHz)- 84903 : Provide BL control signal(DC level, PWM, SM bus), and enable ON/OFF signal.C Source : Chroma 6500/61500/61600 Series

  • Universal Signal Conditioner

    Model UDA - tecsis LP

    Model UDA is a universal signal conditioner and amplifier designed for use with all full bridge, strain gage-based transducers. Model UDA turns the analog signal into a user-selectable output of ±5Vdc, ±10Vdc, or 4-20mA. This versatile unit features selectable excitation of 2.5 or 5.0Vdc bridge voltage and has a wide DC power input range from 11 to 28Vdc to adapt to a variety of installations. Model UDA includes a wide zero and span adjustment range and a symmetry adjustment for applications requiring precision in both tension and compression. The configurable low pass filter actively removes unwanted high frequency signal components. The unit is housed in a rugged DIN-mountable enclosure with screw terminals to provide connection for power, analog output, shunt calibration, and sensor signals.

  • Multifunction Calibrator 15 ppm Basic Accuracy

    MC142 - Powertek LLC

    Multifunction calibrator MC142 is a precision voltage, current and power calibration source serving as a measurement standard in calibration laboratories and production lines; where verification of electrical measurement equipment & sensors is required. It can be used for calibration and adjustment of meters measuring voltage, current, power, resistance, capacitance and frequency. Internal harmonic and non-harmonic signals make it possible to test electrical performance of meters using signals with various crest factors. Frequency modes enable selection of frequency, amplitude and duty cycle of the output signal. These are suitable for basic calibration of digital and analog oscilloscopes along with transient recorders. The calibrator is equipped to measure temperature with TC and RTD temperature sensors. Its built-in multimeter can be used independently or simultaneously with the calibrator output. Testing of transducers of various types, regulators and sensors can be performed, without the necessity to use any other measuring instrument.

  • NanoVIP® TWO™ PLUS

    Elcontrol Energy Net S.r.l.

    NanoVIP® TWO PLUS™ is a modern, compact and powerful portable Power Quality analyzer for professional use; it can be used on single-phase, two-phase, three-phase balanced networks, low and medium voltage as well as on chillers and pumping system to monitor all performance parameters.In addition to its electrical channels, it has 4 sensor channels to read whichever type of transducer: 4..20mA, 0..1V or PT to monitor and store data of whichever system.Thanks to the MRH™ hardware onboard, it can be connected to a QUADRA measuring network as a DGP device.A long lasting battery and the huge logging capability of data (over 1 year) are distinguishing characteristics that make it an absolute reliable and unique professional tool.

  • Circuit Breaker Analyzers & Timers

    CAT Advanced Series - IBEKO Power AB

    DV Power circuit breaker analyzer and timer utilizes the latest technological enhancements for safe and fast testing of circuit breakers. The sophisticated design ensures efficient and reliable operations in high-voltage substations and industrial environments.The CAT Advanced series are stand-alone or PC-controlled digital instruments for a circuit breaker testing. The timing channels record closing and an opening of the arcing, resistor, and auxiliary contacts. Also, the main contact channels can measure the resistance value of the pre-insertion resistors (if present in the circuit breaker).With CAT Advanced series instruments, it is possible to record graphs of open and close coil currents. Furthermore, it records displacements of the HV and MV circuit breaker moving parts. Test results can be saved via USB, PC or be printed via 112 mm (4.4 inches) thermal printer (optional accessory) in tabular and graphical form.A circuit breaker test consists of different operational modes and CAT Advanced series supports:Open (O)Close (C)Reclose (O-0,3s-C)Trip free (CO)O-0,3s-COOpen-Close (O-C)Close-Open (C-O)Open-Close-Open (O-C-O)First trip (O)Multiple operations, such as Open-Close and Open-Close-Open, can be initiated by using a predefined delay time or by sensing a breaker’s contact position.The auxiliary inputs are used to monitor dry and wet auxiliary contacts. The six coil control analog channels measure and record coil currents simultaneously (OPEN and CLOSE), up to 35 A AC/DC.The additional six voltage analog channels have four selectable voltage ranges available (±1 V, ±5 V, ±60 V and ±300 V AC/DC).A built-in micro-ohmmeter generates up to 500A true DC ripple-free current with an automatically regulated test ramp that provides performing static and dynamic contact resistance measurement.Three transducer channels provide a measuring displacement of the circuit breaker moving parts, contact wipe, over-travel, rebound, damping time and average velocity. Also, a user can connect either an analog or a digital transducer to these universal channels.

  • ISP Programmer Superpro Is01

    Xeltek

    Features:Until now,Support IC manufacturer, pcs devices and keeps growing.1)High speed thanks to the flexible hardware engine. Programming speed adjustable for complicated application environments brought by user target board, length of ISP cable etc.2)Stand-alone and PC-Hosted (USB2.0 High Speed) dual mode;3)Supports ISP programming of devices with I2C, SPI, UART, BDM, MON, MW, JTAG, CAN, ICC, RS232 and any other serial port.4)ATE interface;5)Over-current and ESD protection to protect your equipment;6)DLL and API for easy integration into customers’ system.Hardware Specifications:1) ISP cable integrates I2C, SPI, UART, BDM, MON, MW, JTAG, CAN, ICC, RS232 interfaces。2) VDD (0-5.5V /0.5A) and Vpp (0-15V / 0.2A) lines provided to power the target board and the target devices.3) Cable driver circuit supports target devices of voltage level 1.5-5V and is ESD protected.4) USB 2.0 (high speed) interface for PC hosted mode and management of project files on SD card.5) A 20 Characters x 4 lines LCD and a 6-key keypad are built with it for stand-alone operation. In stand-alone mode project files are stored on the SD card (up to 16GB). The number of the project files is limited only by the capacity of the SD card.6) ATE interface is built for easy external hardware control. 6 lines SEL0-SEL5 are for project selection (maximum 64 files); 2 command lines START and STOP; 3 STATUS lines PASS, FAIL and BUSY. All signals are optical-isolated.7) A universal AC adaptor of DC12V/2A is included for power supply.8)WINDOWS XP/Vista/Win7/Win8/Win10 32/64bit compatibility.Software Specifications:1) Supports almost all devices with ISP interface.2) Supports Jam and Staple files from ACTEL and ALTERA; Direct C files from ACTEL.3) Programming speed selectable (High, Normal and Low) for complicated applications such as different cable lengths, different target load characters.4) Dynamic buffer function. Application examples include device S/N, MAC address, frequency or transducer calibration etc.5) File format on SD: FAT16, FAT32.6) Functions for IP protection: Project security, SD security, batch control, administration management etc. 7) API and DLL provided for easy integration into customers’ system like ICT and ATE.8) Software provides the features for multiple units to work concurrently controlled by USB HUB.Applications:1)R&D application like in-circuit test and debug.2)Volume production. Devices may be programmed after the board is fully assembled. One example is the serial number writing to an on-board serial device.3)Field application. Comes with portability, stand-alone mode and mobile data storage media (SD card), it is suitable for field test, debug and data acquisition.4)Third application modules. Friend s/w interface (DLL and Virtual Com communication command set) and h/w interface ( ATE and USB) are provided and make it very easy for customers to integrate ISP01 as a functional module into their systems. One example is the ICT equipment. With this integration user can finish in-circuit test and in-circuit programming in one step.